• DD2.5 DD10 Deuterium Lamp ace bulb Power Supply for 752N 754N

    Price:   $59.00

    • Model: DD2.5 DD10
    • Shipping Weight: 0.1kg
    • 5783 Units in Stock


    Please Choose:

    SIZE CHART
    The color temperature values of commonly used products at home are generally: halogen spotlights, incandescent lamps (2700k yellow), background lights, LED spotlights (3000k warm yellow), kitchen lights, balcony lights, spotlights, cabinet lights, study lights (4000k medium Warm white), living room lights, bedroom lights, etc. (6500k positive white light).
    Measurement Guide

    How to Take Measurements

    1. 1 Select type There are many types of light bulbs, such as tungsten filament bulbs, tungsten filament halogen bulbs, metal halogen bulbs, LED bulbs, xenon bulbs, energy-saving lamps, etc. Most home decorations will use LED bulbs, fluorescent lamps, halogen lamps, and energy-saving lamps. light bulb. 2 Select brightness Brightness is the rate of light energy emitted by a light source or the flow rate of light. Lumens is a unit of measurement for measuring the rate of light output. The light output released by a 400-lumen LED bulb is equivalent to that of a 35-watt incandescent bulb, but its consumption is The power is only 6.3 watts. Generally speaking, if it is an LED light bulb, 1 square meter of space requires 1-3 watts of light bulbs. Consumers can choose according to actual needs. 3 power consumption CFLs use far less energy than traditional incandescent bulbs, so you can choose based on light output (lumens) rather than power consumption (watts), which is a unit of measurement for power consumption. 4 color temperature In our eyes, the light emitted by most light sources is generally called white light. In fact, the white light emitted by different light sources appears to the naked eye to have different colors depending on the color temperature. The more bluish the light color, the higher the color temperature; the more reddish the light color, the lower the color temperature. Bulbs with more of the red spectrum produce a milder light, ideal for relaxation or general lighting, while cooler-toned lights are suitable for work or for focused light. 5 Lamp holder size Common lamp holder sizes are E17 and E14. E17 is a lamp holder with a screw diameter of 17 mm. It is generally used for household use, while E40 is rare or even non-existent in ordinary households. Since the size of each lamp holder is different, be sure to get it before purchasing. Know the size of the lamp head you need so that it will not be inoperable after purchase. It is recommended to bring the old light bulb with you when purchasing to prevent the problem of discrepancy in the size of the lamp head after purchase.

    -+     
    (complete orders today,deliverd around 09/05/2024)
    New Products
    Miniature lamp 240v 5w Ba9s t10x28 A025 GREAT
    $1.19  $1.08-9%
    Miniature light 240v 8w ba15s T16X46 A009 NEW
    $1.99  $1.23-38%
    Miniature Lamp bulbs E12 110V 15W A1215
    $1.39
    GREAT!Miniature lamp bulbs 110/130V 6/10W E14 T16X45 A719
    $1.99  $1.29-35%
    • Details
    • Reviews
    • Tags
    • FAQ

    DD2.5 DD10 Deuterium Lamp UV Spectrophotometer Accessories 2.5/10V Power Supply for 752N 754N 756MC 751GD Laboratory Instruments

    Model :DD2.5 Glass shell outer diameter :30mm Length :70 mm Deuterium lamp belongs to the gas discharge lamp type arc discharge in a light source. Its working out from a window light radiation when the continuous distribution of 160 nm to 400 nm uv spectrum. It is the ideal uv ultraviolet spectrophotometer, liquid chromatograph light source. Note: 1, lamp light center height can be designed according to user requirements. Type 2, arrange ushering installation shape, can design according to user requirements. Directions for use: 1, light three lead, the two are of the same color filament, the other for the anode. 2, after installation and debugging, need to use alcohol cotton swab window light, so as to avoid pollution, affect the uv transmittance. 3, in order to guarantee the stability of the tubes has good demand the stability of the supporting power of no less than 0.05%. 4, tube work, must not look at light, so as not to hurt the eyes. 5, the lamp can count with Japan, Germany, the UK type lamp switch general.

     

    Model :DD10 Glass shell outer diameter :30mm Length :70 mm Deuterium lamp belongs to the gas discharge lamp type arc discharge in a light source. Its working out from a window light radiation when the continuous distribution of 160 nm to 400 nm uv spectrum. It is the ideal uv ultraviolet spectrophotometer, liquid chromatograph light source. Note: 1, lamp light center height can be designed according to user requirements. Type 2, arrange ushering installation shape, can design according to user requirements. Directions for use: 1, light three lead, the two are of the same color filament, the other for the anode. 2, after installation and debugging, need to use alcohol cotton swab window light, so as to avoid pollution, affect the uv transmittance. 3, in order to guarantee the stability of the tubes has good demand the stability of the supporting power of no less than 0.05%. 4, tube work, must not look at light, so as not to hurt the eyes. 5, the lamp can count with Japan, Germany, the UK type lamp switch general.

     

    Deuterium Arc Lamp Power Supply Input voltage: AC 85 ~ 265V Max input current: 0.5A Filament voltage: preheat: 10V DC, lit after: DC6~7V Maximum anode voltage: preheat: 125V DC, lit after: 80V DC Anode current: 300mA Constant current accuracy: 0.05 per thousand (on 1H) Minimum trigger voltage: 400V DC Pressure: 1500V AC / 1min Turn off the lights: 3 ~ 12V / 1 mA Volume: 130 * 99 * 40 mm3 Weight: 0.4KG Through the "CE" certification, access to national invention patent.

     